The Nz function will return 0 if there are no records so this expression will return a 1 the first time and then increment the highest number each additional time. The key is where to put this line of code. As I said it needs to be generated immediately prior to saving the record so that another user does not get the same number. So generally I would put this behind a Save button or a button to specifically generate the number. I would then add a second line to commit the records. Either:
Even worse (I found out from bitter experience), is that whenever a computer “glitch” (aka “crash”) or “upgrade” (e.g. to a new/different desktop) came along, and our outside IT vendor had to “fix” the “computer” or “system,” (always, of course, at unexpected and unpredictable times), all of my “Auto Text” blocks got “wiped out” (or, I could not find them, even after a few help desk calls), and I had to “reinvent” and “re-keystroke” or “re-save” each of them again (and several times, again). Obviously, frustrating, and largely defeating the efficiency purpose.

I have a document where in I have to make two kinds of page numbering, A catalog (individually made) which should always start at page 1, and the other is a compiled version where the pages should be a continuous page. They both have the same content but with different output so I tried using layers, but fail to set the page numbering to auto. because setting them would affect both layers.


I have been researching using sequential numbers for invoices an purchase orders, but all of them seem to advance the number eithe every time the document is opened or saved. My purchase order is par of a larger file, and since I will be opening and saving the fil without necessarily writing a purchase order I need more control ove its advancement. I was wondering how I could create a button that whe pressed or selected would advance the number by 1? Also, how could make it create a unique number depending on who's creating the purchas order. For example, let's say the user is ...
Does anybody have a way of formatting the phone numbers in Outlook 2003 so that they appear as xxx yyy zzzz that is no dashes, no parentheses? If I am going to synch to my PDA I want the numbers as short as possible and, to me, as readable as possible. Steve No. Masking of phone numbers is hard coded and based on your default dialing location. -- Russ Valentine [MVP-Outlook] "Steve E." wrote in message news:2dd601c48eb8$3ff4a1e0$a601280a@phx.gbl... > Does anybody have a way of formatting the phone numbers in > Outlook 2003 so that they appear as x...
A single InDesign document can contain up to 9,999 pages, but page numbers can be as large as 999,999. (For example, you can correctly number a 100‑page document that starts on page 9,949.) By default, the first page is a recto (right) page numbered 1. Odd-numbered pages always appear on the right; if you use the Section Options command to change the first page number to an even number, the first page becomes a verso (left) page.
To define a sequence by recursion, one needs a rule to construct each element in terms of the ones before it. In addition, enough initial elements must be provided so that all subsequent elements of the sequence can be computed by the rule. The principle of mathematical induction can be used to prove that in this case, there is exactly one sequence that satisfies both the recursion rule and the initial conditions. Induction can also be used to prove properties about a sequence, especially for sequences whose most natural description is recursive.
I would like to number a voucher book, i have place 4 vouchers on a page, the thing is that i want each of these vouchers to start with different number, 100, 200, 300, 400, and then i want to number them 99 times. The problem is that they have to be numbered only 1 per page, so that when i have printed them all i can easily crop them and staple them right up with having to go through it all.
The Artifact ID should NOT be your PK. There is no reason for it to be and to try and use it as such will be a headache. A primary key is simply a unique identifier for a record. Many purists will tell you that users should never see the PK and in your case, I would recommend that. Use an Autonumber as you PK and you can use that as your corresponding Foreign Key in related records. To prevent duplication you can make the combination of Collection Point ID and Artifact ID a unique, multi-field index. Then display the combination as I indicated where you need to show the user a record ID. This is all explained int he blog.
I have several xml files (SMS backup files) I am editing where I want to insert sequential numbering. The number in the id field shown in bold italics below has been replaced with a unique string to allow for a find and replace to be done sequentially giving, e.g. xml a) containing id's 1 to 25, xml b) containing id's 26 to 50, xml c) containing id's 51 to 75 and so on.
Each section within an InDesign document can be numbered differently. This allows you to use one type of numerals to consecutively number a document's preface or other introductory materials and another numeral system for the remainder of the document. You must first define your document's sections, and then you can add section markers or page markers to your master pages. Apply the master page to document pages to include the section and page numbers on the document pages.

Hi All, I am working on a YTD Sales report. I would like to know if I can create a cell in a query that will be a squential number. Starting with 1 on up. If so how would I do this? Report would look something like: Num Customer YTD Sales 1 Bobs Sales 495,000 2 Denny's 395,000 3 Biffs Supply 390,000 4.... -- Matt Campbell mattc (at) saunatec [dot] com Message posted via http://www.accessmonster.com You can use a text box in the report: Control Source: =1 Running Sum: Over All -- Duane Hookom Microsoft Access MVP "mattc66 via AccessMo...


Angie, have tried your method; however, I encountered what I surmised was a limit on the amount of characters allowed in that “Enter formatting for number” box: for instance, I can only type as far as “Request for Productio” (excluding quotations)- additional text and codes delete and default back to the incomplete phrase “Request for Productio”. Seems to have a default of 26 characters – anything exceeding that is deleted. The phrase “Request for Admission” completes, but am unable to include anything after that phrase of 26 characters. Not sure why that is, but that’s what I run into when I attempt using the multi-list option.
 I'm looking for a script for Laserfiche Forms that will query a database and pull the next number in sequence and display it as the unique identifier for this document.  Once this number has been used, the number should not be used again.  This is similar to what the Submission ID is, but from what I can gather, this number is assigned after the submission takes place.  
CK Note: Word 2007 - 2013 interface has an different automatic numbering scheme which I have been told is much less subject to corruption. Microsoft Word 2010 Bible by Herb Tyson, MVP. However numbering is still very imperfect in these later versions. I still recommend following Shauna Kelly's step-by-step instructions (see above) if setting up numbering in a template or in a document likely to be heavily edited. If you start without doing this and end up with "spaghetti numbering," fixing it will be a very large chore!
Scott, I had posted on Microsoft and you sent me to your blog to have the numbering system (similar to APEX example) explained. I am not a programmer and I don’t understand where these codes and expressions are even suppose to go in access. When I do try to implement the little I do know I continue to get errors. I am not sure if I am putting the information in the wrong place or if I am way off. Do you know of any youtube videos that could walk me through it step by step? Or if you have the time could you help walk me through the steps.
I’m not sure which version of InDesign first introduced printing Thumbnails like this, but even if yours doesn’t support that, your printer driver may have a similar feature of its own. Check the printer’s own dialog box by clicking “Setup…” near the bottom left corner of the Print dialog and dismissing the warning, then clicking “Preferences…” in Windows’s Print dialog that comes up (I’m not sure how to access this on Mac OS X, but I’m pretty sure there’s an easy way). For instance, on many HP printers, the feature you want is called “Pages per sheet” and has a drop-down offering 1, 2, 4, 9, or 16 pages per sheet.
Tip  Follow the same steps (above) to create Request for Production or Request for Admissions. The only difference would be in Step 3, you would change the "rog" to "rpf" or "rfa". This will keep unique numbering schemes running in the same document. Therefore, you could have an Interrogatory No.1 as well as Request for Production No.1. Keep in mind that if you cut, copy or paste sequence codes, you'll need to select them and press F9 to update the field codes. They do not update automatically.
sequential numbering labeller paper rotary sequential numbering machine sequential numbering machine sequential number sequential numbering machines sequential number barcode label printing embossed sequential numbers card sequential number plastic card sequential number adhesive sticker sequential labeling sequentially numbered stickers sequentially barcoded labels sequential labels custom sequential number label printing
Now, what’s the deal with the UniqueKeyVariant parameter for the RowNumber() function? We are not even using it all! True, but if we didn’t, Access will call RowNumber() only once for an entire query and thus we get “1” for the entire dataset. That is a good way to save on CPU processing – why call Now() for each row? In this case, we want to go against this CPU-saving measure and ensure that the RowNumber() is in fact called once per row to generate a new number for that row. Thus, we pass in a parameter — a primary key of a table is a good choice for this purpose. So we get a nice sequential number generated all in the query with VBA function.
You can change the numbers in the list by restarting the sequence or by specifying a new start number. You can change the list's style. You can do anything to this list that you can do to a normal numbered list because it is a numbered list, with one exception: the list, while easy to format, is fixed. If you delete an item, the list updates accordingly, but I haven't found a way to add numbers.
×